How much do you know about the vertical slurry pump? Today, we will briefly introduce the reasons for its insufficient traffic, and hope that it can help you to use it in the future.
1. The system has a static head increase. The treatment method is to check the liquid height and the system pressure;
2. The resistance loss increases. The treatment method is to check the pipeline and the stop valve and other obstacles;
3. The casing and impeller wear ring wears too much. The treatment method is to replace or repair the wear ring and the impeller;
4. Other parts leak. The treatment method is to check the shaft seal and the like;
5. The vertical slurry pump is not turning right and the speed is too low. The treatment method is to check the rotation direction and check the rotation speed;
6. The impeller of the vertical slurry pump is blocked, worn and corroded. The treatment method is cleaning, inspection and exchange.